{"id":4182,"date":"2021-11-26T17:05:38","date_gmt":"2021-11-26T15:05:38","guid":{"rendered":"https:\/\/siatkibezpieczenstwa.com\/safety-nets\/s-system-safety-nets\/"},"modified":"2026-09-05T20:29:07","modified_gmt":"2026-09-05T18:29:07","slug":"s-system-safety-nets","status":"publish","type":"page","link":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/","title":{"rendered":"Horizontal safety nets, S system \u2013 border rope according to EN 1263-1"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"4182\" class=\"elementor elementor-4182 elementor-209\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1d3f44f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1d3f44f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-86c3430\" data-id=\"86c3430\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7365cc4 elementor-share-buttons--skin-flat elementor-share-buttons--shape-rounded elementor-share-buttons--view-icon-text elementor-grid-0 elementor-share-buttons--color-official elementor-widget elementor-widget-global elementor-global-4132 elementor-global-2379 elementor-widget-share-buttons\" data-id=\"7365cc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"share-buttons.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-grid\" role=\"list\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_twitter\" role=\"button\" tabindex=\"0\" aria-label=\"Share on twitter\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-twitter\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M459.37 151.716c.325 4.548.325 9.097.325 13.645 0 138.72-105.583 298.558-298.558 298.558-59.452 0-114.68-17.219-161.137-47.106 8.447.974 16.568 1.299 25.34 1.299 49.055 0 94.213-16.568 130.274-44.832-46.132-.975-84.792-31.188-98.112-72.772 6.498.974 12.995 1.624 19.818 1.624 9.421 0 18.843-1.3 27.614-3.573-48.081-9.747-84.143-51.98-84.143-102.985v-1.299c13.969 7.797 30.214 12.67 47.431 13.319-28.264-18.843-46.781-51.005-46.781-87.391 0-19.492 5.197-37.36 14.294-52.954 51.655 63.675 129.3 105.258 216.365 109.807-1.624-7.797-2.599-15.918-2.599-24.04 0-57.828 46.782-104.934 104.934-104.934 30.213 0 57.502 12.67 76.67 33.137 23.715-4.548 46.456-13.32 66.599-25.34-7.798 24.366-24.366 44.833-46.132 57.827 21.117-2.273 41.584-8.122 60.426-16.243-14.292 20.791-32.161 39.308-52.628 54.253z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tTwitter\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_pinterest\" role=\"button\" tabindex=\"0\" aria-label=\"Share on pinterest\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-pinterest\" viewBox=\"0 0 496 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M496 256c0 137-111 248-248 248-25.6 0-50.2-3.9-73.4-11.1 10.1-16.5 25.2-43.5 30.8-65 3-11.6 15.4-59 15.4-59 8.1 15.4 31.7 28.5 56.8 28.5 74.8 0 128.7-68.8 128.7-154.3 0-81.9-66.9-143.2-152.9-143.2-107 0-163.9 71.8-163.9 150.1 0 36.4 19.4 81.7 50.3 96.1 4.7 2.2 7.2 1.2 8.3-3.3.8-3.4 5-20.3 6.9-28.1.6-2.5.3-4.7-1.7-7.1-10.1-12.5-18.3-35.3-18.3-56.6 0-54.7 41.4-107.6 112-107.6 60.9 0 103.6 41.5 103.6 100.9 0 67.1-33.9 113.6-78 113.6-24.3 0-42.6-20.1-36.7-44.8 7-29.5 20.5-61.3 20.5-82.6 0-19-10.2-34.9-31.4-34.9-24.9 0-44.9 25.7-44.9 60.2 0 22 7.4 36.8 7.4 36.8s-24.5 103.8-29 123.2c-5 21.4-3 51.6-.9 71.2C65.4 450.9 0 361.1 0 256 0 119 111 8 248 8s248 111 248 248z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tPin\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_linkedin\" role=\"button\" tabindex=\"0\" aria-label=\"Share on linkedin\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-linkedin\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 32H31.9C14.3 32 0 46.5 0 64.3v383.4C0 465.5 14.3 480 31.9 480H416c17.6 0 32-14.5 32-32.3V64.3c0-17.8-14.4-32.3-32-32.3zM135.4 416H69V202.2h66.5V416zm-33.2-243c-21.3 0-38.5-17.3-38.5-38.5S80.9 96 102.2 96c21.2 0 38.5 17.3 38.5 38.5 0 21.3-17.2 38.5-38.5 38.5zm282.1 243h-66.4V312c0-24.8-.5-56.7-34.5-56.7-34.6 0-39.9 27-39.9 54.9V416h-66.4V202.2h63.7v29.2h.9c8.9-16.8 30.6-34.5 62.9-34.5 67.2 0 79.7 44.3 79.7 101.9V416z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tShare\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_email\" role=\"button\" tabindex=\"0\" aria-label=\"Share on email\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-envelope\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M502.3 190.8c3.9-3.1 9.7-.2 9.7 4.7V400c0 26.5-21.5 48-48 48H48c-26.5 0-48-21.5-48-48V195.6c0-5 5.7-7.8 9.7-4.7 22.4 17.4 52.1 39.5 154.1 113.6 21.1 15.4 56.7 47.8 92.2 47.6 35.7.3 72-32.8 92.3-47.6 102-74.1 131.6-96.3 154-113.7zM256 320c23.2.4 56.6-29.2 73.4-41.4 132.7-96.3 142.8-104.7 173.4-128.7 5.8-4.5 9.2-11.5 9.2-18.9v-19c0-26.5-21.5-48-48-48H48C21.5 64 0 85.5 0 112v19c0 7.4 3.4 14.3 9.2 18.9 30.6 23.9 40.7 32.4 173.4 128.7 16.8 12.2 50.2 41.8 73.4 41.4z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tEmail\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_whatsapp\" role=\"button\" tabindex=\"0\" aria-label=\"Share on whatsapp\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-whatsapp\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M380.9 97.1C339 55.1 283.2 32 223.9 32c-122.4 0-222 99.6-222 222 0 39.1 10.2 77.3 29.6 111L0 480l117.7-30.9c32.4 17.7 68.9 27 106.1 27h.1c122.3 0 224.1-99.6 224.1-222 0-59.3-25.2-115-67.1-157zm-157 341.6c-33.2 0-65.7-8.9-94-25.7l-6.7-4-69.8 18.3L72 359.2l-4.4-7c-18.5-29.4-28.2-63.3-28.2-98.2 0-101.7 82.8-184.5 184.6-184.5 49.3 0 95.6 19.2 130.4 54.1 34.8 34.9 56.2 81.2 56.1 130.5 0 101.8-84.9 184.6-186.6 184.6zm101.2-138.2c-5.5-2.8-32.8-16.2-37.9-18-5.1-1.9-8.8-2.8-12.5 2.8-3.7 5.6-14.3 18-17.6 21.8-3.2 3.7-6.5 4.2-12 1.4-32.6-16.3-54-29.1-75.5-66-5.7-9.8 5.7-9.1 16.3-30.3 1.8-3.7.9-6.9-.5-9.7-1.4-2.8-12.5-30.1-17.1-41.2-4.5-10.8-9.1-9.3-12.5-9.5-3.2-.2-6.9-.2-10.6-.2-3.7 0-9.7 1.4-14.8 6.9-5.1 5.6-19.4 19-19.4 46.3 0 27.3 19.9 53.7 22.6 57.4 2.8 3.7 39.1 59.7 94.8 83.8 35.2 15.2 49 16.5 66.6 13.9 10.7-1.6 32.8-13.4 37.4-26.4 4.6-13 4.6-24.1 3.2-26.4-1.3-2.5-5-3.9-10.5-6.6z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tWhatsApp\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-891badd elementor-align-left elementor-widget elementor-widget-global elementor-global-4124 elementor-global-3400 elementor-widget-breadcrumbs\" data-id=\"891badd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"breadcrumbs.default\">\n\t\t\t\t\t<p id=\"breadcrumbs\"><span><span><a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/collective-protection-equipment\/\">Home<\/a><\/span><\/span><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1678c3 elementor-widget elementor-widget-text-editor\" data-id=\"d1678c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>System S represents the most common form of safety netting encountered on construction sites:<\/strong> a large, horizontal safety net suspended beneath the working level, bounded by a heavy-duty border rope (perimeter rope) and tied directly to the building structure. Its purpose is to arrest a falling person rather than fence them off from an edge<span data-path-to-node=\"11,2\">. This allows workers to move freely across the entire protected net area without harnesses or lanyards restricting their range of movement<\/span><span data-path-to-node=\"11,4\">. <strong>It is a key component of temporary Collective Protection Equipment (CPE) used during the erection of commercial buildings, industrial hall roofs, and precast concrete floor slab assembly<\/strong><\/span><span data-path-to-node=\"11,6\"><strong>.<\/strong>\u00a0<\/span>Below, we detail exactly what System S entails under the EN 1263-1 standard, its minimum allowable dimensions, how fall height and catch width are calculated, the required clear fall space underneath, and the required strength ratings for ropes and anchorage points.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ac41d8 gallery-spacing-custom elementor-widget elementor-widget-image-gallery\" data-id=\"0ac41d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-gallery.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-image-gallery\">\n\t\t\t<div id='gallery-1' class='gallery galleryid-4182 gallery-columns-3 gallery-size-large'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"0ac41d8\" data-elementor-lightbox-title=\"Horizontal safety netting system S EN 1263-1\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDAwNSwidXJsIjoiaHR0cHM6XC9cL3NpYXRraWJlenBpZWN6ZW5zdHdhLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyMVwvMTJcL3NpYXRraS1iZXpwaWVjemVuc3R3YS1TLndlYnAiLCJzbGlkZXNob3ciOiIwYWM0MWQ4In0%3D\" href='https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S.webp'><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"449\" src=\"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S.webp\" class=\"attachment-large size-large\" alt=\"Horizontal safety netting system S EN 1263-1 mounted beneath roof beams for fall protection\" srcset=\"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S.webp 800w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S-300x168.webp 300w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S-150x84.webp 150w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S-768x431.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"0ac41d8\" data-elementor-lightbox-title=\"Horizontal S-system safety nets EN 1263-1\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDAwNCwidXJsIjoiaHR0cHM6XC9cL3NpYXRraWJlenBpZWN6ZW5zdHdhLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyMVwvMTJcL3NpYXRraS1hc2VrdXJhY3lqbmUtUy53ZWJwIiwic2xpZGVzaG93IjoiMGFjNDFkOCJ9\" href='https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-asekuracyjne-S.webp'><img decoding=\"async\" width=\"800\" height=\"449\" src=\"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-asekuracyjne-S.webp\" class=\"attachment-large size-large\" alt=\"Horizontal S-system safety nets EN 1263-1 stretched across steel roof trusses of a hall\" srcset=\"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-asekuracyjne-S.webp 800w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-asekuracyjne-S-300x168.webp 300w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-asekuracyjne-S-150x84.webp 150w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-asekuracyjne-S-768x431.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"0ac41d8\" data-elementor-lightbox-title=\"Safety netting S EN 1263-1\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDAwNiwidXJsIjoiaHR0cHM6XC9cL3NpYXRraWJlenBpZWN6ZW5zdHdhLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyMVwvMTJcL3NpYXRraS1iaHAtUy53ZWJwIiwic2xpZGVzaG93IjoiMGFjNDFkOCJ9\" href='https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S.webp'><img decoding=\"async\" width=\"800\" height=\"449\" src=\"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S.webp\" class=\"attachment-large size-large\" alt=\"Safety netting S EN 1263-1 covering large steel roof bays while trapezoidal sheeting is installed\" srcset=\"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S.webp 800w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S-300x168.webp 300w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S-150x84.webp 150w, https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S-768x431.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9cc971c elementor-widget elementor-widget-heading\" data-id=\"9cc971c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What the S system is, and what sets it apart from the other EN 1263-1 systems<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-227f5d3 elementor-widget elementor-widget-text-editor\" data-id=\"227f5d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>EN 1263-1 standard distinguishes four safety net systems. <strong>Whether a net is classified as System S depends on one defining element: the border rope.<\/strong> This is a heavy-duty rope that passing through every perimeter mesh of the net, defining its external dimensions. It is the border rope that transfers the impact load from the netting to the building structure, and it is tied directly to anchorage points\u2014never individual mesh strands. The netting mesh itself features square or diamond openings measuring under 100 mm, with mesh strands manufactured from High-Tenacity (HT) polyamide or polypropylene. The minimum energy absorption capacity of the netting is 2.3 kJ. The dynamic impact test for System S safety nets involves dropping a smooth 100 kg steel sphere twice onto the net from a height delivering 7 kJ of kinetic energy \u2014 corresponding approximately to seven meters.\u00a0The three remaining netting systems address different situations and we covered on dedicated pages:<\/p>\n<ul>\n<li><strong>System T<\/strong> \u2013 a net fixed to horizontal cantilever brackets, installed storey by storey along the fa\u00e7ade. Read more under <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/t-system-safety-nets\/\"><strong><u>system T safety nets<\/u>.<\/strong><\/a><\/li>\n<li><strong>System V<\/strong> \u2013 a net with border rope on gallows-type brackets, suspended vertically along slab edges. Read more under <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/safety-netting-type-v\/\"><strong><u>system V safety nets<\/u>.<\/strong><\/a><\/li>\n<li><strong>System U<\/strong> \u2013 A vertical safety net attached to a supporting framework, used as a protective wall during roofing, scaffolding, or open edge work. This is how our edge barrier system works, as described under <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/roof-edge-netting\/\"><strong><u>hall and roof edge protection<\/u>.<\/strong><\/a><\/li>\n<\/ul>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bce55e4 elementor-widget elementor-widget-heading\" data-id=\"bce55e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Minimum required size: 35 m\u00b2 and shorter side 5 m<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7afae5d elementor-widget elementor-widget-text-editor\" data-id=\"7afae5d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>System S has a mandatory minimum size requirement, which is its most significant practical limitation<span data-path-to-node=\"19,2\">. <strong>A System S safety net must have a surface area of at least 35m2, with its shortest side measuring at least 5.0 meters (Clause 5.1 of EN 1263-2).<\/strong> Below these dimensions, the netting simply cannot deflect sufficiently to absorb dynamic fall energy. During a person fall, small nets lack adequate deflection in it, resulting in a sharp, dangerous surge in impact force transmitted to both the human body and the structural anchorage points.\u00a0<\/span><strong>Nets smaller than 35 m2 are outside the scope of the EN 1263 standard\u2014the standard does not prohibit them; it simply does not cover them<\/strong><span data-path-to-node=\"20,2\"><strong>.<\/strong> Since there are no standard requirements to evaluate them against, <strong>there is no legal basis to issue an EN 1263 Declaration of Conformity<\/strong> <strong>for small nets<\/strong> in System S<\/span><span data-path-to-node=\"20,4\">. If a supplier offers you a small net claimed to be &#8220;certified under EN 1263&#8221;, it is worth to request the actual document and check what it specifically covers<\/span><span data-path-to-node=\"20,6\">.\u00a0<\/span>In practice, this means System S is not the appropriate solution for securing small openings\u2014such as roof skylights, elevator shafts, or individual floor voids<span data-path-to-node=\"21,2\">. For skylight fall protection, dedicated systems are required, which we cover on our page for <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/roof-safety-solutions\/skylight-railing\/\"><strong><u>skylight protection<\/u>.<\/strong><\/a><\/span><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1ef021 elementor-widget elementor-widget-heading\" data-id=\"b1ef021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fall height and catch width<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9afafe1 elementor-widget elementor-widget-text-editor\" data-id=\"9afafe1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Safety netting must be installed as close below the working level as possible<span data-path-to-node=\"23,2\">. Fall height is defined as the vertical distance between the protected working edge and the point of impact on the net<\/span><span data-path-to-node=\"23,4\">. The standard limits fall height to two threshold values: no more than 6 m under normal conditions, and no more than 3 m within the edge zone (defined as the perimeter belt within 2 m of the net border). These requirements derive directly from the energy absorption capacity of the netting.<\/span><\/p>\n<p>Catch width &#8211; the horizontal distance between the outer edge of the work area and the outer edge of the safety net\u2014depends directly on the vertical fall height:<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c1e62d elementor-widget elementor-widget-text-editor\" data-id=\"3c1e62d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ac-tabla-wrap\">\r\n<table class=\"ac-tabla ac-tabla--num\" style=\"min-width: 560px;\" aria-label=\"Minimalna szeroko\u015b\u0107 chwytania siatki bezpiecze\u0144stwa w zale\u017cno\u015bci od wysoko\u015bci spadku\">\r\n<thead>\r\n<tr>\r\n<th scope=\"col\"><strong>Fall Height (He\u200b)<\/strong><\/th>\r\n<th scope=\"col\">\u2264 1,0 m<\/th>\r\n<th scope=\"col\">\u2264 3,0 m<\/th>\r\n<th scope=\"col\">\u2264 6,0 m<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<th scope=\"row\"><strong>Min. Catch Width (b)<\/strong><\/th>\r\n<td>\u2265 2,0 m<\/td>\r\n<td>\u2265 2,5 m<\/td>\r\n<td>\u2265 3,0 m<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/div><br><p class=\"ac-tabla-nota\">Values according to EN 1263. On working surfaces inclined by more than 20\u00b0 the catch width is at least 3.0 m.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b03d484 elementor-widget elementor-widget-text-editor\" data-id=\"b03d484\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>A specific condition applies to sloped work surfaces exceeding a <span data-math=\"20^\\circ\" data-index-in-node=\"65\">20\u00b0 pitch: the catch width must be at least 3 m, and the distance between the farthest working point and the lowest point along the net edge must not exceed 3m.<\/span><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af3c070 elementor-widget elementor-widget-heading\" data-id=\"af3c070\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Required fall clearance under the net<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d158d1c elementor-widget elementor-widget-text-editor\" data-id=\"d158d1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Safety netting arrests a fall by deflecting. Therefore, sufficient clear space must remain underneath so that a falling worker does not strike any rigid obstacles or ground surfaces as the net deforms<\/strong><span data-path-to-node=\"28,4\"><strong>.<\/strong> Dynamic deflection depends on the shorter side length of the net and the fall height<\/span><span data-path-to-node=\"28,6\">.\u00a0<\/span>The standard defines this through two key formulas: initial deflection should not exceed one-tenth of the shorter side length, and the total vertical distance including initial deflection must not exceed <span data-math=\"6.0\\text{ m}\" data-index-in-node=\"225\">6 m. <strong>Furthermore, if traffic routes or lower working levels exist beneath the net, an additional safety margin must be kept<\/strong>\u2014ensuring clear distance remains greater than zero even at maximum dynamic deflection. This critical clearance dimension is often overlooked during site planning and frequently determines whether horizontal netting can be installed at a given location<\/span><span data-path-to-node=\"29,6\">.<\/span><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6abb087 elementor-widget elementor-widget-heading\" data-id=\"6abb087\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Net suspension: ropes, anchorage points and structural loads<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a7344e elementor-widget elementor-widget-text-editor\" data-id=\"0a7344e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>System S safety nets are secured to the host structure via the border rope, using tie ropes*, carabiners, shackles, or bracket hooks. The distance between individual attachment points must not exceed <\/strong><span data-math=\"2.5\\text{ m}\" data-index-in-node=\"221\"><strong>2,5 m<\/strong>, and each suspension point must be engineered to withstand a characteristic load of at least 6 kN. The force distribution along the net border is non-uniform: load at corner anchors is zero, rising toward the span center in a characteristic sequence\u20144 kN, 6 kN, 4 kN. <\/span><\/p>\n<p data-path-to-node=\"32\"><em data-path-to-node=\"32\" data-index-in-node=\"0\">*with a breaking strength of 30 kN for a single-branch rope, or 15 kN for a two-branch rope<\/em><\/p>\n<p>Below you will find the required strengths of the individual components in a table:<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18a98fc elementor-widget elementor-widget-text-editor\" data-id=\"18a98fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"ac-tabla-wrap\">\r\n<table class=\"ac-tabla ac-tabla--spec\" style=\"min-width: 560px;\" aria-label=\"Wymagane wytrzyma\u0142o\u015bci lin i punkt\u00f3w mocowania siatki bezpiecze\u0144stwa typu S\">\r\n<thead>\r\n<tr>\r\n<th scope=\"col\">Component<\/th>\r\n<th scope=\"col\">Required strength<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<th scope=\"row\">Border rope<\/th>\r\n<td>above 30 kN (safety factor 2)<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Tie rope \u2013 single-branch suspension<\/th>\r\n<td>at least 30 kN<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Tie rope \u2013 two-branch suspension<\/th>\r\n<td>at least 15 kN<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Coupling rope (joining nets)<\/th>\r\n<td>at least 7,5 kN<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Individual attachment point<\/th>\r\n<td>at least 6 kN<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Spacing of attachment points<\/th>\r\n<td>maximum 2,5 m<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Galvanised steel cables<\/th>\r\n<td>above 50 kN<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Galvanised carabiners with safety nut<\/th>\r\n<td>above 20 kN<\/td>\r\n<\/tr>\r\n<tr>\r\n<th scope=\"row\">Minimum energy absorption of the net<\/th>\r\n<td>2,3 kJ<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/div><br><p class=\"ac-tabla-nota\">Values from EN 1263-1 and from the instructions for use supplied with the product.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-547537d elementor-widget elementor-widget-text-editor\" data-id=\"547537d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Two separate safety nets are joined by means of a certified coupling rope (Type O, min. <span data-math=\"7.5\\text{ kN}\" data-index-in-node=\"82\">7,5 kN breaking strength) woven mesh by mesh through both net panels and tied at opposite corners. Any gap created between connected net borders must not exceed 100 mm. Alternatively, net panels may overlap by a minimum width of 2 m. <\/span><\/p>\n<p>When securing large floor slab openings\u2014such as atriums, lightwells, or shafts\u2014the border rope is threaded through cast-in or drilled rebar hooks spaced every <span data-math=\"50\\text{ cm}\" data-index-in-node=\"159\">50 cm along the slab edge<\/span><span data-path-to-node=\"35,2\">. Hooks are made of \u00a0\u00d88mm ribbed rebar anchored into \u00d820 mm holes to a minimum depth of 15 cm and positioned at least 10 cm back from the slab edge.<\/span><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ddd5b8 elementor-widget elementor-widget-heading\" data-id=\"7ddd5b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Applications of System S safety nets in construction<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6bb3a3 elementor-widget elementor-widget-text-editor\" data-id=\"f6bb3a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Horizontal type S safety netting serves as core collective fall protection across key construction sector:<\/p>\n<ul>\n<li><strong>Steel and Precast Concrete Hall Roofs:<\/strong> Securing open roof bays during trapezoidal sheeting, sandwich panel laying, skylight fitting, and flat roof insulation<span data-path-to-node=\"38,0,0,2\">. Combined with <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/roof-edge-netting\/\"><strong><u>perimeter edge protection system such as RAND+<\/u><\/strong><\/a>, they deliver complete fall protection during height works.<\/span><\/li>\n<li><strong>Large slab openings and shafts: <\/strong>Securing atrium voids, elevator shafts, service openings, and mezzanines on commercial building sites<span data-path-to-node=\"38,1,0,2\">.<\/span><\/li>\n<li><strong>Bridge construction: <\/strong>Underslung fall arrest protection for crews performing formwork and rebar assembly below bridge decks<span data-path-to-node=\"38,2,0,2\">. Specialized civil engineering setups are covered under <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/bridge-edge-protection\/\"><strong><u>bridge and viaduct protection<\/u>.<\/strong><\/a><\/span><\/li>\n<li><strong>Fixed and movable nets systems: <\/strong>Across expansive industrial halls, System S nets can be fixed permanently beneath the entire roof structure or suspended from steel messenger cables with pulleys\/travelling carabiners, moving progressively alongside installation works.<\/li>\n<\/ul>\n<p>Fine Debris Overlay: Where work above a System S net generates falling mortar, concrete chips, or involves small hand tools, a fine debris mesh is overlaid onto the primary net.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ec0cac elementor-widget elementor-widget-heading\" data-id=\"6ec0cac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Labelling, test mesh and mandatory annual inspection<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cb04ec elementor-widget elementor-widget-text-editor\" data-id=\"6cb04ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Under EN 1263-1, every safety net must carry a permanently sewn-in factory label specifying:<\/strong> manufacturer name, manufacture date, net classification (system and mesh size), precise product description, minimum energy absorption capacity, mesh breaking strength, and the mark of an accredited independent inspection body authorised to inspect nets. The absence of any of these items is a critical a warning sign.<\/p>\n<p><strong>Attached to the net perimeter are loose fibre tests meshes bearing the exact same serial number as the main label.<\/strong> This is the only valid method to verify that a test mesh belongs to that specific net. Synthetic fibres (polypropylene and polyamide) undergo gradual strength loss due to solar UV radiation. <strong>To extend the certified operational validity of a safety net for an additional 12 months, one test mesh is cut<\/strong> prior to the end of the 1-year period and submitted to the manufacturer&#8217;s testing laboratory to verify tensile breaking strength. A passing test result re-certifies the safety net for another year of active service.<\/p>\n<p><strong>A safety net must be removed from service immediately if it has arrested a person fall or heavy object impact<\/strong> (unless re-tested), if its energy absorption capacity is no longer guaranteed, or if visible damage appear: severe abrasion, severed mesh strands, or damaged border ropes and loops. Storage conditions directly dictate whether a safety net passes its annual test. Nets must be stored in dry, well-ventilated areas, away from direct heat sources and sunlight, and completely separated from aggressive chemicals such as acids, alkalis, solvents, or oils.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdd88fe elementor-widget elementor-widget-heading\" data-id=\"fdd88fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ \u2013 frequently asked questions about type S safety nets<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db4d2f4 elementor-widget elementor-widget-accordion\" data-id=\"db4d2f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"accordion.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-2291\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2291\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><svg class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><svg class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">What is the minimum required size for System S safety net?<\/a>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\t<div id=\"elementor-tab-content-2291\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2291\"><p>A minimum surface area of at least <span data-math=\"35\\text{ m}^2\" data-index-in-node=\"96\">35 m\u00b2 with a short side measuring no less than 5 meters. This is a strict requirement under Clause 5.1 of EN 1263-2, not merely a manufacturer recommendation. Nets smaller than those dimensions fall outside the scope of EN 1263\u2014they are not forbidden, but because no standard criteria exist for them, no valid EN Declaration of Conformity can be issued for a System S net below these dimensions.<\/span><\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-2292\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2292\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><svg class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><svg class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">What is the required breaking strength for the border rope on a System S net?<\/a>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\t<div id=\"elementor-tab-content-2292\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2292\"><p>The border rope (passing through every perimeter mesh) must have a tensile breaking strength exceeding <span data-math=\"30\\text{ kN}\" data-index-in-node=\"181\">30 kN<\/span>, incorporating a safety factor of 2. It is made of high-tenacity polyamide and tested in full compliance with EN 1263-1.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-2293\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2293\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><svg class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><svg class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Which ropes are used to install System S nets and what are their required strengths?<\/a>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\t<div id=\"elementor-tab-content-2293\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2293\"><p>The tie rope is used to attach the border rope of a type S net to the supporting structure. It has the same strength as the border rope itself \u2014 above 30 kN \u2014 when suspended on a single branch (single tie rope); on a two-branch suspension 15 kN is sufficient (double tie rope). Coupling ropes (type O) are used to join adjacent net panels to one another. They must have a strength a minimum breaking strength of 7.5 kN.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-2294\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2294\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><svg class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><svg class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Can a System S safety net be anchored to timber structures?<\/a>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\t<div id=\"elementor-tab-content-2294\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2294\"><p>The EN standard does not restrict the building material itself, but specifies the structural load each anchor point must sustain: at least <span data-math=\"6\\text{ kN}\" data-index-in-node=\"199\">6 kN, with anchor spacing not exceeding 2.5 m. Thus, feasibility depends on the structural load capacity of the specific member rather than its material. On concrete slabs, rebar hooks are anchored into slab edges; on steel halls, tie ropes loop around structural members. On timber structures, anchorage method is evaluated individually based on engineering drawings, as timber grade and cross-section dictate load capacity. Send us your structural drawings and our team will verify anchorage points prior to quoting.<\/span><\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<h3 id=\"elementor-tab-title-2295\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2295\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><svg class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><svg class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">What is the maximum allowable fall height onto a System S safety net?<\/a>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\t<div id=\"elementor-tab-content-2295\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2295\"><p>The maximum vertical fall distance from the working surface onto the net is <span data-math=\"6.0\\text{ m}\" data-index-in-node=\"146\">6 m. However, within a 2 m perimeter belt along the anchored net edge, the fall height must not exceed 3 m. Best safety practice dictates suspending the net as close below the working level as possible.<\/span><\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the minimum required size for System S safety net?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>A minimum surface area of at least <span data-math=\\\"35\\\\text{ m}^2\\\" data-index-in-node=\\\"96\\\">35 m\\u00b2 with a short side measuring no less than 5 meters. This is a strict requirement under Clause 5.1 of EN 1263-2, not merely a manufacturer recommendation. Nets smaller than those dimensions fall outside the scope of EN 1263\\u2014they are not forbidden, but because no standard criteria exist for them, no valid EN Declaration of Conformity can be issued for a System S net below these dimensions.<\\\/span><\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"What is the required breaking strength for the border rope on a System S net?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>The border rope (passing through every perimeter mesh) must have a tensile breaking strength exceeding <span data-math=\\\"30\\\\text{ kN}\\\" data-index-in-node=\\\"181\\\">30 kN<\\\/span>, incorporating a safety factor of 2. It is made of high-tenacity polyamide and tested in full compliance with EN 1263-1.<\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"Which ropes are used to install System S nets and what are their required strengths?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>The tie rope is used to attach the border rope of a type S net to the supporting structure. It has the same strength as the border rope itself \\u2014 above 30 kN \\u2014 when suspended on a single branch (single tie rope); on a two-branch suspension 15 kN is sufficient (double tie rope). Coupling ropes (type O) are used to join adjacent net panels to one another. They must have a strength a minimum breaking strength of 7.5 kN.<\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"Can a System S safety net be anchored to timber structures?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>The EN standard does not restrict the building material itself, but specifies the structural load each anchor point must sustain: at least <span data-math=\\\"6\\\\text{ kN}\\\" data-index-in-node=\\\"199\\\">6 kN, with anchor spacing not exceeding 2.5 m. Thus, feasibility depends on the structural load capacity of the specific member rather than its material. On concrete slabs, rebar hooks are anchored into slab edges; on steel halls, tie ropes loop around structural members. On timber structures, anchorage method is evaluated individually based on engineering drawings, as timber grade and cross-section dictate load capacity. Send us your structural drawings and our team will verify anchorage points prior to quoting.<\\\/span><\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"What is the maximum allowable fall height onto a System S safety net?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>The maximum vertical fall distance from the working surface onto the net is <span data-math=\\\"6.0\\\\text{ m}\\\" data-index-in-node=\\\"146\\\">6 m. However, within a 2 m perimeter belt along the anchored net edge, the fall height must not exceed 3 m. Best safety practice dictates suspending the net as close below the working level as possible.<\\\/span><\\\/p>\\n\"}}]}<\/script>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31415e9 elementor-widget elementor-widget-heading\" data-id=\"31415e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Do you need a type S netting for a specific project?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f80e843 elementor-widget elementor-widget-text-editor\" data-id=\"f80e843\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Are you planning industrial hall roofing, precast concrete slab installation, or floor void protection<span data-path-to-node=\"51,2\">? <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/contact\/\"><strong><u>Contact our engineering team today<\/u><\/strong><\/a><\/span><strong>.<\/strong><\/p>\n<p>System S is just one of four safety net configurations defined under the EN 1263 standard. If you are not sure which of them best fits your building, explore our complete guide: <a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/\"><strong><u>a comparison of all safety net arrangements: S, T, U and V<\/u>.<\/strong><\/a><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43768bf elementor-share-buttons--skin-flat elementor-share-buttons--shape-rounded elementor-share-buttons--view-icon-text elementor-grid-0 elementor-share-buttons--color-official elementor-widget elementor-widget-global elementor-global-4132 elementor-global-2379 elementor-widget-share-buttons\" data-id=\"43768bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"share-buttons.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-grid\" role=\"list\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_twitter\" role=\"button\" tabindex=\"0\" aria-label=\"Share on twitter\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-twitter\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M459.37 151.716c.325 4.548.325 9.097.325 13.645 0 138.72-105.583 298.558-298.558 298.558-59.452 0-114.68-17.219-161.137-47.106 8.447.974 16.568 1.299 25.34 1.299 49.055 0 94.213-16.568 130.274-44.832-46.132-.975-84.792-31.188-98.112-72.772 6.498.974 12.995 1.624 19.818 1.624 9.421 0 18.843-1.3 27.614-3.573-48.081-9.747-84.143-51.98-84.143-102.985v-1.299c13.969 7.797 30.214 12.67 47.431 13.319-28.264-18.843-46.781-51.005-46.781-87.391 0-19.492 5.197-37.36 14.294-52.954 51.655 63.675 129.3 105.258 216.365 109.807-1.624-7.797-2.599-15.918-2.599-24.04 0-57.828 46.782-104.934 104.934-104.934 30.213 0 57.502 12.67 76.67 33.137 23.715-4.548 46.456-13.32 66.599-25.34-7.798 24.366-24.366 44.833-46.132 57.827 21.117-2.273 41.584-8.122 60.426-16.243-14.292 20.791-32.161 39.308-52.628 54.253z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tTwitter\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_pinterest\" role=\"button\" tabindex=\"0\" aria-label=\"Share on pinterest\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-pinterest\" viewBox=\"0 0 496 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M496 256c0 137-111 248-248 248-25.6 0-50.2-3.9-73.4-11.1 10.1-16.5 25.2-43.5 30.8-65 3-11.6 15.4-59 15.4-59 8.1 15.4 31.7 28.5 56.8 28.5 74.8 0 128.7-68.8 128.7-154.3 0-81.9-66.9-143.2-152.9-143.2-107 0-163.9 71.8-163.9 150.1 0 36.4 19.4 81.7 50.3 96.1 4.7 2.2 7.2 1.2 8.3-3.3.8-3.4 5-20.3 6.9-28.1.6-2.5.3-4.7-1.7-7.1-10.1-12.5-18.3-35.3-18.3-56.6 0-54.7 41.4-107.6 112-107.6 60.9 0 103.6 41.5 103.6 100.9 0 67.1-33.9 113.6-78 113.6-24.3 0-42.6-20.1-36.7-44.8 7-29.5 20.5-61.3 20.5-82.6 0-19-10.2-34.9-31.4-34.9-24.9 0-44.9 25.7-44.9 60.2 0 22 7.4 36.8 7.4 36.8s-24.5 103.8-29 123.2c-5 21.4-3 51.6-.9 71.2C65.4 450.9 0 361.1 0 256 0 119 111 8 248 8s248 111 248 248z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tPin\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_linkedin\" role=\"button\" tabindex=\"0\" aria-label=\"Share on linkedin\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-linkedin\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 32H31.9C14.3 32 0 46.5 0 64.3v383.4C0 465.5 14.3 480 31.9 480H416c17.6 0 32-14.5 32-32.3V64.3c0-17.8-14.4-32.3-32-32.3zM135.4 416H69V202.2h66.5V416zm-33.2-243c-21.3 0-38.5-17.3-38.5-38.5S80.9 96 102.2 96c21.2 0 38.5 17.3 38.5 38.5 0 21.3-17.2 38.5-38.5 38.5zm282.1 243h-66.4V312c0-24.8-.5-56.7-34.5-56.7-34.6 0-39.9 27-39.9 54.9V416h-66.4V202.2h63.7v29.2h.9c8.9-16.8 30.6-34.5 62.9-34.5 67.2 0 79.7 44.3 79.7 101.9V416z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tShare\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_email\" role=\"button\" tabindex=\"0\" aria-label=\"Share on email\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-envelope\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M502.3 190.8c3.9-3.1 9.7-.2 9.7 4.7V400c0 26.5-21.5 48-48 48H48c-26.5 0-48-21.5-48-48V195.6c0-5 5.7-7.8 9.7-4.7 22.4 17.4 52.1 39.5 154.1 113.6 21.1 15.4 56.7 47.8 92.2 47.6 35.7.3 72-32.8 92.3-47.6 102-74.1 131.6-96.3 154-113.7zM256 320c23.2.4 56.6-29.2 73.4-41.4 132.7-96.3 142.8-104.7 173.4-128.7 5.8-4.5 9.2-11.5 9.2-18.9v-19c0-26.5-21.5-48-48-48H48C21.5 64 0 85.5 0 112v19c0 7.4 3.4 14.3 9.2 18.9 30.6 23.9 40.7 32.4 173.4 128.7 16.8 12.2 50.2 41.8 73.4 41.4z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tEmail\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_whatsapp\" role=\"button\" tabindex=\"0\" aria-label=\"Share on whatsapp\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-whatsapp\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M380.9 97.1C339 55.1 283.2 32 223.9 32c-122.4 0-222 99.6-222 222 0 39.1 10.2 77.3 29.6 111L0 480l117.7-30.9c32.4 17.7 68.9 27 106.1 27h.1c122.3 0 224.1-99.6 224.1-222 0-59.3-25.2-115-67.1-157zm-157 341.6c-33.2 0-65.7-8.9-94-25.7l-6.7-4-69.8 18.3L72 359.2l-4.4-7c-18.5-29.4-28.2-63.3-28.2-98.2 0-101.7 82.8-184.5 184.6-184.5 49.3 0 95.6 19.2 130.4 54.1 34.8 34.9 56.2 81.2 56.1 130.5 0 101.8-84.9 184.6-186.6 184.6zm101.2-138.2c-5.5-2.8-32.8-16.2-37.9-18-5.1-1.9-8.8-2.8-12.5 2.8-3.7 5.6-14.3 18-17.6 21.8-3.2 3.7-6.5 4.2-12 1.4-32.6-16.3-54-29.1-75.5-66-5.7-9.8 5.7-9.1 16.3-30.3 1.8-3.7.9-6.9-.5-9.7-1.4-2.8-12.5-30.1-17.1-41.2-4.5-10.8-9.1-9.3-12.5-9.5-3.2-.2-6.9-.2-10.6-.2-3.7 0-9.7 1.4-14.8 6.9-5.1 5.6-19.4 19-19.4 46.3 0 27.3 19.9 53.7 22.6 57.4 2.8 3.7 39.1 59.7 94.8 83.8 35.2 15.2 49 16.5 66.6 13.9 10.7-1.6 32.8-13.4 37.4-26.4 4.6-13 4.6-24.1 3.2-26.4-1.3-2.5-5-3.9-10.5-6.6z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-share-btn__text\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__title\">\n\t\t\t\t\t\t\t\t\t\tWhatsApp\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a7f7bfb elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a7f7bfb\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c069e29\" data-id=\"c069e29\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3985233 elementor-widget elementor-widget-shortcode\" data-id=\"3985233\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\t\t<div data-elementor-type=\"section\" data-elementor-id=\"4138\" class=\"elementor elementor-4138 elementor-1337 elementor-1337\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c9e92b1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c9e92b1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-80e3845\" data-id=\"80e3845\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-92d94d3 elementor-widget elementor-widget-heading\" data-id=\"92d94d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">RELATED SYSTEMS<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e91dbc5 elementor-skin-carousel elementor-arrows-yes elementor-pagination-type-bullets elementor-pagination-position-outside elementor-widget elementor-widget-media-carousel\" data-id=\"e91dbc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;slides_per_view&quot;:&quot;5&quot;,&quot;space_between&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:1,&quot;sizes&quot;:[]},&quot;slides_per_view_tablet&quot;:&quot;2&quot;,&quot;space_between_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:5,&quot;sizes&quot;:[]},&quot;skin&quot;:&quot;carousel&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;show_arrows&quot;:&quot;yes&quot;,&quot;pagination&quot;:&quot;bullets&quot;,&quot;speed&quot;:500,&quot;autoplay&quot;:&quot;yes&quot;,&quot;autoplay_speed&quot;:5000,&quot;loop&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;space_between_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:10,&quot;sizes&quot;:[]}}\" data-widget_type=\"media-carousel.default\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-main-swiper swiper\" role=\"region\" aria-roledescription=\"carousel\" aria-label=\"Slides\">\n\t\t\t\t<div class=\"swiper-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"Horizontal safety netting system S EN 1263-1 mounted beneath roof beams for fall protection\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/safety-netting-type-v\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"Type V EN 1263 perimeter safety net system protecting construction workers on upper building floor\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-V.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/t-system-safety-nets\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"T-system safety nets mounted on metal brackets fixed under the slab of a building\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-asekuracyjne-T.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/falling-materials-netting\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"Falling debris protection netting erected over pedestrian walkway at urban construction site\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/zabezpieczenie-spadkiem-przedmiotow.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/roof-edge-netting\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"Roof net enclosing the whole perimeter of an industrial hall before roofing\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/zabezpieczenie-krawedzi-hal-siatkami.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/bridge-edge-protection\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"Bridge edge protection netting on posts along a bridge on construction\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-krawedzi-mostow.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/roof-anchoring\/fall-arrest-slings\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"Fall arrest sling EN 795 class A1 used while receiving crane loads on a construction site\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/Punkty-zaczepowe-tasmowy-EN795.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/siatkibezpieczenstwa.com\/en\/roof-anchoring\/temporary-horizontal-lifeline\/\" target=\"_blank\">\t\t<div class=\"elementor-carousel-image\" role=\"img\" aria-label=\"Formwork fall protection system securing a worker installing timber floor shuttering\" style=\"background-image: url(&#039;https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/zabezpieczenie-prac-szalunkowych.webp&#039;)\">\n\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t<\/a>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-prev\" role=\"button\" tabindex=\"0\" aria-label=\"Previous\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-eicon-chevron-left\" viewBox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z\"><\/path><\/svg>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-next\" role=\"button\" tabindex=\"0\" aria-label=\"Next\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-eicon-chevron-right\" viewBox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z\"><\/path><\/svg>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-pagination\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Twitter Pin Share Email WhatsApp System S represents the most common form of safety netting encountered on construction sites: a large, horizontal safety net suspended beneath the working level, bounded by a heavy-duty border rope (perimeter rope) and tied directly to the building structure. Its purpose is to arrest a falling person rather than fence [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":4177,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"plain-container","ast-site-content-layout":"normal-width-container","site-content-style":"unboxed","site-sidebar-style":"unboxed","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-4182","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.4 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Horizontal Safety Nets \u2013 S System to EN 1263-1<\/title>\n<meta name=\"description\" content=\"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Horizontal safety nets, S system \u2013 border rope according to EN 1263-1 | AITANA SAFETY\" \/>\n<meta property=\"og:description\" content=\"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/\" \/>\n<meta property=\"og:site_name\" content=\"AITANA SAFETY\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-05T18:29:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:description\" content=\"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/\",\"url\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/\",\"name\":\"Horizontal Safety Nets \u2013 S System to EN 1263-1\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/siatki-bezpieczenstwa-S.webp\",\"datePublished\":\"2021-11-26T15:05:38+00:00\",\"dateModified\":\"2026-09-05T18:29:07+00:00\",\"description\":\"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/#primaryimage\",\"url\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/siatki-bezpieczenstwa-S.webp\",\"contentUrl\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/siatki-bezpieczenstwa-S.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/safety-nets\\\/s-system-safety-nets\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/collective-protection-equipment\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Construction safety nets \u2013 collective fall protection to EN 1263\",\"item\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/siatki-asekuracyjne\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Horizontal safety nets, S system \u2013 border rope according to EN 1263-1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/\",\"name\":\"AITANA SAFETY\",\"description\":\"Fall arrest systems supplier\",\"publisher\":{\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/#organization\",\"name\":\"AITANA SAFETY\",\"url\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/sygnet-512x512_RGB.jpg\",\"contentUrl\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/sygnet-512x512_RGB.jpg\",\"width\":512,\"height\":512,\"caption\":\"AITANA SAFETY\"},\"image\":{\"@id\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/aitana-safety\\\/\",\"https:\\\/\\\/www.pinterest.com\\\/aitanasafety\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCUR94GYiO0MMUAD7DgK6XNg\"],\"description\":\"Supply and installation of roof safety systems. Roof safety railings EN 14122-3, collective protection measures and safety nets EN 1263\",\"email\":\"biuro@siatkibezpieczenstwa.com\",\"telephone\":\"+48 661 131 486\",\"vatID\":\"PL 7822066483\",\"taxID\":\"PL 7822066483\",\"publishingPrinciples\":\"https:\\\/\\\/siatkibezpieczenstwa.com\\\/regulamin-serwisu\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Horizontal Safety Nets \u2013 S System to EN 1263-1","description":"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/","og_locale":"en_US","og_type":"article","og_title":"Horizontal safety nets, S system \u2013 border rope according to EN 1263-1 | AITANA SAFETY","og_description":"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!","og_url":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/","og_site_name":"AITANA SAFETY","article_modified_time":"2026-09-05T18:29:07+00:00","og_image":[{"url":"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bhp-S.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_description":"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/","url":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/","name":"Horizontal Safety Nets \u2013 S System to EN 1263-1","isPartOf":{"@id":"https:\/\/siatkibezpieczenstwa.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/#primaryimage"},"image":{"@id":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/#primaryimage"},"thumbnailUrl":"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S.webp","datePublished":"2021-11-26T15:05:38+00:00","dateModified":"2026-09-05T18:29:07+00:00","description":"Horizontal safety nets, S system to EN 1263-1. Fall protection for hall roofs and floor slabs. Custom sizing. Request a B2B quote!","breadcrumb":{"@id":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/#primaryimage","url":"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S.webp","contentUrl":"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/12\/siatki-bezpieczenstwa-S.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/siatkibezpieczenstwa.com\/en\/safety-nets\/s-system-safety-nets\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/siatkibezpieczenstwa.com\/en\/collective-protection-equipment\/"},{"@type":"ListItem","position":2,"name":"Construction safety nets \u2013 collective fall protection to EN 1263","item":"https:\/\/siatkibezpieczenstwa.com\/en\/siatki-asekuracyjne\/"},{"@type":"ListItem","position":3,"name":"Horizontal safety nets, S system \u2013 border rope according to EN 1263-1"}]},{"@type":"WebSite","@id":"https:\/\/siatkibezpieczenstwa.com\/en\/#website","url":"https:\/\/siatkibezpieczenstwa.com\/en\/","name":"AITANA SAFETY","description":"Fall arrest systems supplier","publisher":{"@id":"https:\/\/siatkibezpieczenstwa.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/siatkibezpieczenstwa.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/siatkibezpieczenstwa.com\/en\/#organization","name":"AITANA SAFETY","url":"https:\/\/siatkibezpieczenstwa.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/siatkibezpieczenstwa.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/11\/sygnet-512x512_RGB.jpg","contentUrl":"https:\/\/siatkibezpieczenstwa.com\/wp-content\/uploads\/2021\/11\/sygnet-512x512_RGB.jpg","width":512,"height":512,"caption":"AITANA SAFETY"},"image":{"@id":"https:\/\/siatkibezpieczenstwa.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/aitana-safety\/","https:\/\/www.pinterest.com\/aitanasafety\/","https:\/\/www.youtube.com\/channel\/UCUR94GYiO0MMUAD7DgK6XNg"],"description":"Supply and installation of roof safety systems. Roof safety railings EN 14122-3, collective protection measures and safety nets EN 1263","email":"biuro@siatkibezpieczenstwa.com","telephone":"+48 661 131 486","vatID":"PL 7822066483","taxID":"PL 7822066483","publishingPrinciples":"https:\/\/siatkibezpieczenstwa.com\/regulamin-serwisu\/"}]}},"_links":{"self":[{"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/pages\/4182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/comments?post=4182"}],"version-history":[{"count":5,"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/pages\/4182\/revisions"}],"predecessor-version":[{"id":7333,"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/pages\/4182\/revisions\/7333"}],"up":[{"embeddable":true,"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/pages\/4177"}],"wp:attachment":[{"href":"https:\/\/siatkibezpieczenstwa.com\/en\/wp-json\/wp\/v2\/media?parent=4182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}